% Urea Measurement

Due to ISO 22241-2 standards Urea percentage of AdBlue must match
with %31,8-%33,2 value gap. Low percentage levels causes rise of emission rates and “Nonconforming AdBlue” fault warnings on vehicle info units.

Materials To Be Used In The Test

You can see the materials to be used in the test in the image below.

% Urea Measurement

Due to ISO 22241-2 standards Urea percentage of AdBlue must match
with %31,8-%33,2 value gap. Low percentage levels causes rise of emission rates and “Nonconforming AdBlue” fault warnings on vehicle info units.

[ WARNING ! ] Before measurement, sample temperature level must be set to 20C with ice bath or
heater according to weather conditions

Materials To Be Used In The Test

You can see the materials to be used in the test in the image below.

How To Make % Urea Measurement?

1

Take Urea Refractometer device located in Section 2. 

üre

2

 Clean prism surface of device with clean and soft fabric. (Be careful for prism surface)

14

3

 Perform Reset Procedure on device with pure water.

15

4

Reset Procedure : Drip aprox. 10 drops of pure water with Pipette located in Section 2. Press Start button and activate the device than press Zero button to set the value to “0” on screen.
[ WARNING ! ] Please be careful to avoid air bubbles in pure water and do not overflow while drippingto perform test in right conditions.

16

5

 Clean and dry prism surface of device with clean and soft fabric. (Be careful for prism surface)

17

6

Drip aprox. 10 drops of AdBlue sample with Pipette on prism surface. After 3 time screen flashing with “OK” sign read the values from screen for Urea Percentage and Sample Temperature Value and note.

18

7

Clean prism surface of device with pure water and dry with clean and soft fabric than press and hold the Start button until off.

19

How To Make % Urea Measurement?

üre

1

Take Urea Refractometer device located in Section 2. 

14

2

Clean prism surface of device with clean and soft fabric. (Be careful for prism surface)

15

3

Perform Reset Procedure on device with pure water.

16

4

Reset Procedure : Drip aprox. 10 drops of pure water with Pipette located in Section 2. Press Start button and activate the device than press Zero button to set the value to “0” on screen.
[ WARNING ! ] Please be careful to avoid air bubbles in pure water and do not overflow while drippingto perform test in right conditions.

17

5

Clean and dry prism surface of device with clean and soft fabric. (Be careful for prism surface)

18

6

Drip aprox. 10 drops of AdBlue sample with Pipette on prism surface. After 3 time screen flashing with “OK” sign read the values from screen for Urea Percentage and Sample Temperature Value and note.

19

7

Clean prism surface of device with pure water and dry with clean and soft fabric than press and hold the Start button until off.

Blue Analysis 3D

Address
İstasyon Mah. No:10 Kartepe/Kocaeli

Phone
+90 262 373 68 28

E-Mail
info@blueanalysis.com.tr

About Us

Blue Analysis test bag; Euro 4, 5 and 6 norm diesel fueled heavy duty vehicles, trucks, buses, trucks and new generation passenger cars used to reduce the exhaust emissions Adblue chemical pre-test to ensure the quality of the test bag.

Tests

Clarity Test
Oil Test
Urea Measurement
Refractive Index Measurement
Density Measurement
Aldehyde Amount Test

Blue Analysis 3D

Address
İstasyon Mah. No:10 Kartepe/Kocaeli

Phone
+90 262 373 68 28

E-Mail
info@blueanalysis.com.tr

About Us

Blue Analysis test bag; Euro 4, 5 and 6 norm diesel fueled heavy duty vehicles, trucks, buses, trucks and new generation passenger cars used to reduce the exhaust emissions Adblue chemical pre-test to ensure the quality of the test bag.

Tests

Clarity Test
Oil Test
Urea Measurement
Refractive Index Measurement
Density Measurement
Aldehyde Amount Test